Canon multipass c3000 Service Manual (en)

Download
5.2.5 New SSSWs/parameters added to this model
#1 SSSW (service soft switch setting)
SW01 (service soft switch 01: error management)
Bit
Function
1
0
0
Service error code
Output
Not output
1
Error dump list
Output
Not output
2
Not used
3
Copy function
No
Yes
4
##300 series service error code
Output
Not output
5
Not used
6
Date & Time setting restriction
Setting restricted
Setting possible
7
Not used
[Bit 4]
Even when Bit0 is set to "Not output", you can select whether or not to output ##300
series Service Error Codes, caused by hardware malfunction.
When "Output" is selected, ##300 series Service Error Codes are displayed and in
reports.
When "Not Output" is selected, no Service Error Codes are displayed.
#3 NUMERIC PARAM (numeric parameter settings)
No.
Function
Selecting range
Default setting
10
T0 Timer
0~9999
5500 (55 second)
11
T1 Timer (Rx)
0~9999
3500 (35 second)
13
Maximum time to receive
500~3000
1300 (13 second)
one line of image data
[Parameter 10]
The "wait time after transmission of a dialing signal ends until a significant signal is
detected in transmission" was set as T1 timer with parameter 10.
However, ITU-T recommends that it should be set as T0 timer, so parameter 10 has
been renamed to T0 timer and the default time-out time has been changed from 35 to
55 seconds.
The T1 timer for the transmitter (wait time after a CED, V21 flag, or
ANSam significant signal is detected until the next significant signal is
detected) is fixed at 35 seconds.
[Parameter 11]
Set the T1 timer for the receiver (wait time after DIS transmission starts until a
significant signal is received).
If frequent errors occur during reception (2 instances) because of line connection
conditions, raise the value of this parameter.
[Parameter 13]
Set the maximum time to receive one line of image data when image data is received.
If the other party is a computer fax and the time to receive one line of image data is
long, raise the value of this parameter to increase the maximum reception (2 instances)
time.
Chapter 3: Maintenance & Service
3-41
NOTE