59
5
S
et
ting P
age
[Subdirectory Name to Create], [File Name to 
Create] 
If file naming is set to [User Setting], enter the 
subdirectory name to be created as well as the 
name of the created file (using up to 127 
characters). Parameters can be specified in the 
entry with the “%” character (p. 147).
(7) [FTP Upload Test] 
Clicking [Exec] initiates an upload test based on the 
settings currently entered. Only one JPEG image is 
uploaded. It is not necessary to click [Apply].
For a password, first click [Exec], then [Apply] the 
password.
E-mail Notification
(1) [Notification] 
Select [Text Only] or [Text with Image] as the content 
of notification. If [Upload] is set to [Upload Disabled], 
[Text with Image] will not be available. 
(2) [Mail Server Name] 
Enter the host name or IP address of the SMTP server 
(using up to 63 characters). 
(3) [Mail Server Port] 
Enter the port number of the SMTP server (factory 
default setting is [25]).
(4) [Sender (From)] 
Set the e-mail address of the sender (using up to 63 
characters).
(5) [Recipient (To)] 
Set the e-mail address of the recipient (using up to 63 
characters).
(6) [Authentication] 
Select [None], [POP before SMTP] or [SMTP-AUTH] 
for the e-mail authentication method. 
Set an appropriate method according to the 
authentication method used by the SMTP server to 
send to. 
[User Name], [Password], [POP Server] 
If [POP before SMTP] is selected as the e-mail 
authentication mode, enter the user name and 
password as well as the host name or IP address of 
the POP server required for authentication. 
[User Name], [Password]
If [SMTP-AUTH] is selected as the e-mail 
authentication method, enter the user name and 
password required for authentication. 
(7) [Subject] 
Enter the subject of the e-mail to be sent using up to 
31 ASCII characters. 
(8) [Message Body] 
Enter the message (text) of the e-mail to be sent using 
up to 255 ASCII characters. Parameters can be 
specified with the “%” character (p. 147).
(9) [E-mail Notification Test] 
Clicking [Exec] initiates an e-mail notification test 
based on the settings currently entered. It is not 
necessary to click [Apply].
For a password, first click [Exec], then [Apply] the 