GE Ca-Zoom PTZ 70 Operating Guide (en)

Download
Everest Ca-Zoom
®
 
6.2
4.    Cleaning
Please clean camera head after an inspection.  Use regular water to wipe down cables.  Use 70% 
alcohol to water solution to wipe down the camera head.
4.2    Storage and Shipments
The PTZ system should always be stored in a clean and dry condition.  Storage should be in areas 
protected from extreme temperature and high humidity.
Storage temperature specification: -13° to 140°F (-25° to 60°C), 95% humidity.
4.3    Lamp and Lamp Window Replacement - PTZ40
CAUTION! 
Before performing any maintenance task, make sure camera system is turned off and be sure 
to de-pressurize the camera unit via the Schrader valve (see page 11). Make sure unit is cooled 
down completely. Lamps are extremely hot. 
14   Maintenance
7
To replace the lamp window, follow these steps: 
•  Remove the lamp window-retaining ring by gently prying the end of the ring with a small 
screwdriver. 
•  Gently pry the window out of the housing. 
•  Carefully remove the o-ring from the groove with the supplied o-ring pick. 
•  Clean o-ring groove thoroughly. 
•  Replace o-ring with a new, well-lubricated o-ring. 
•  Replace lamp window. 
•  Install retaining ring by starting on one end and working 
  around the lamp housing until the entire ring is inserted into the groove. 
Lamp Housing
Retaining Ring
Figure 32
Figure 33