GE Ca-Zoom PTZ 70 Operating Guide (en)

Download
Everest Ca-Zoom
®
 
6.2
72
Lamp Replacement: 
•  Remove the metal cap from the lamp housing by grasping the lamp housing cap and turning 
counter clockwise. 
•  Grasp the lamp firmly and pull straight out of the socket, making note of which type of lamp 
(spot or flood) is being removed (this is written on the side of the lamp). 
•  Replace with the same type of lamp (10° spot, 20° medium, or 30° flood). Align the pins of 
the replacement lamp with the holes in the socket and push into the socket until it is seated 
•  Make sure the o-ring is in place and is properly lubricated. If the o-ring appears dry, add a    
thin coat of silicon or Teflon grease. 
•  Slide the metal cap back onto the lamp housing and turn clockwise by hand until the cap fits    
snugly against the housing. There should be no gap between the cap and the housing when 
finished.
4.4   Camera Window Replacement - PTZ40
 
CAUTION! 
Before performing any maintenance task, be sure to de-pressurize the camera unit via the 
Schrader valve (see page 11). 
To replace the camera window, follow these steps: 
•  Remove the camera window-retaining ring using the 
   spanner wrench (fig. 34).
•  Gently pry the window out of the housing (fig. 35). 
•  Carefully remove the o-ring from the groove with the 
   supplied o-ring pick (fig. 36). 
•  Clean o-ring groove thoroughly. 
•  Replace o-ring with a new, well-lubricated o-ring. 
•  Replace camera window. 
•  Install retaining ring by threading it by hand into the 
   camera window opening.  Hand-tighten with spanner
   wrench.  
•  Pressure test camera housing.  See “
Pressure Testing” section on page 82.
Figure 34
Figure 35
Figure 36