GE Ca-Zoom PTZ 70 Operating Guide (en)

Download
Everest Ca-Zoom
®
 
6.2
79
4.9   Lamp Replacement - PTZ70
CAUTION! 
Before performing any maintenance task, make sure camera system is turned off and be sure to 
de-pressurize the camera unit via the Schrader valve (see page 12). 
To replace the camera window, follow these steps: 
•  Remove the four Phillips screw from the front of the camera housing (fig. 59).
•  Remove the lock screw from the rear of the camera housing (fig. 60).
•  Unthread the knurled ring on the back of the camera housing (fig. 61).
•  Gently pull the front half of the housing away from the rear half.  DO NOT TRY TO ROTATE THE  
 TWO HALVES.  THEY ARE KEYED (fig. 62).
•  Disconnect the wiring harnesses (fig. 63).
•  Unplug the wire fro the back of the LED that needs to be removed.
•  Press on the back of the LED with a screwdriver and push it out through the front of the  
 
 housing (fig.64).
•  The window, o-ring, lens and LED will fall out in front of the housing.  Be sure to replace in    
 the same order.
•  Pressure test camera housing.  See “
Pressure Testing” section on page 82.
Figure 59
Figure 60
Figure 6
Figure 62